2026 FAAC PRICE LIST

XKP

With a BUS 2Easy connection, this keypad is very secure. Unlike other systems. If a would be thief was to remove the XKPB from its mounting position and try to short out the wires behind, they would be ignored. The end users pin codes can be between 2 and 4 digits. When connected to a BUS 2Easy compatible board there is the option to have two codes that can be assigned to different functions. For example, the first code would open the gate fully and the second would provide a partial opening for pedestrians only. Alternatively, if the XRB4 is used in conjunction with an XKPB, four codes can be created that are assigned to the four relays on the XBR4. This way one key pad can be used to provide an open command to four sepa rated automation systems.

Part Number

Price (£)

XKP Metal keypad radio version

404038

163.80

Download Datasheet

XKP Metal keypad BUS version

404045

141.75

XBR2 Bus relay 2 channel for non-BUS panels

790064

48.72

Adaptor box for surface cable entry

401064

8.83

Adaptor for column mounting

401065

7.32

Download Manual

Mounting Posts

Specifications

Part Number

Price £

XP20/XP30 Low Support Post H500mm XP20/XP30 High Support Post H1000mm XP20/XP30 Double Support Post H1000mm

401070 401075 401080 737100

68.20

109.30 114.70

12.46

Foundation plate

CDVI car height goose neck post Dual height goose neck post

N-GNP-1C N-GNP-2CL

166.64 net 289.91 net

Safety. If the gate stalls whilst hitting an obstruction, the encoder detects the lack of forward movement and causes a reversal which will prevent a person being pinned by the gate. Energy saving An automatic gate needs to be stopped in both the opening and closing direction. Traditionally this has been done by putting a physical stop, something a simple as a small post in the way of the gates movement. This works because the gate is driven for a set period of time and when it hits the post it just drives on for a little longer. Adding an encoder allows the control board to know the exact position the gate should stop so there is no need to drive up against the physical stops consuming additional power. Security Because the encoder is recording the position of the gate and the control board know what position it should be seeing. When a gate is forced open the control board creates an alarm. This alarm can then be integrated into the sites security system by connecting the boards output. Also alarms are provided to both the installer and gate owner via the Simply Con nect app if Simply Connect has been installed.

The BUS 2Easy connected wireless safety edge receiver, provides a failsafe system with very easy installation and setup. The wireless communication with up to six XTS transmitters allows for edges being installed on the moving gate. A XTS transmitter has two channels which will each monitor an 8K2 resistive safety edge. They are powered by standard 1.5V batteries and offer a very simple solution to wireless. XRS Wireless Safety Edge Receiver

Description

Part Number

Net Price (£)

XTS 868 transmitter

N-787012 N-787013

71.30 85.50

XRS 868 receiver

Radio receiver unit

Additional transmitter

XBR2 & XBR4 Interface Card An interface that allows a connection between FAAC BUS 2Easy devices and any automation system. It converts the BUS 2Easy information into either normally closed or normally open circuits. The XRB2 has two channels and the XRB four has four. Each channel can be used but a single BUS 2Easy device or in some cases a BUS 2Easy device can provide various outputs (see XKPB). XIB Expansion Card Really only used on the E024S. This is an expansion board is inserted into the BUS 2Easy input on a FAAC control board and creates two additional safety circuits. You get an opening safety and closing safety circuit that would be suitable for a safety loops or photo cells. These inputs are not able to provide a failsafe check and so would not be suitable for safety edge signals or XGuards.

139

Made with FlippingBook Digital Proposal Maker