Product catalogue
455D
TECHNICAL SPECIFICATIONS
Power supply voltage
230 Vac (+6% - 10%) - 50 Hz
Absorbed power Motor max. load
10 W
800 W 500 mA
Accessories max. load Electric lock max. load
15VA
Operating ambient temperature
-20 °C to +55 °C
Protection fuses
2
Open/Open free leaf/Stop (closed)/Opening safety devices/Closing safety devices/power supply & earth / opening and closing limit switches
Terminal board inputs
Flashing lamp/motors/24Vdc power supply accessories/24 Vdc Indicator light/fail safe/ 12 Vac electric lock power supply
Terminal board outputs
Rapid connector Status signalling
Decoding cards/RP card receivers
via display
455 D board can control one or two operators
FUNCTIONS (PROGRAMMING BY DISPLAY AND PUSH-BUTTONS) Basic programming Function logics
Semi-automatic / Automatic / Safety / “stepped” semi-automatic / “stepped”automatic / “stepped” safety / Semi-automatic B / “Dead man” C
Open and closing time
Programmable (0 to 120 s) Programmable (0 to 4 min.) Programmable (0 to 4 min.)
Pause time
Closing leaf delay
Thrust power
Adjustable on 50 levels for each motor
Simple (work time self-learning of both leaves simultaneously) Complete (work time “manual” learning of each leaf with possibility to activate timed travel limit “decelerations”)
Work times learning (0 to 120 s)
Deceleration
timed / with limit switch / with gatecoder
Advanced programming Maximum torque at initial thrust
Selectable (useful for heavy-weight leaves)
Final stroke on closing
Selectable (makes the locking of the electric lock easier) Selectable (makes the release of the electric lock easier)
Reversing stroke
Pre-flashing
5 s (selectable)
Opening leaf delay
2 s (can be disabled)
Closing photocell logic Fail safe (photocell test) Electric lock on second leaf
Reverses on release/reverses immediately
Selectable Selectable
Cycle count
Selectable (updating of a “count-down”- max. setting 99.000 thousand cycles)
Selectable (when the number of cycles set by program is “reached”, the system activates a preflashing of 8 s before every opening movement)
Service request
Indicator light/timed output
Selectable (the indicator light output can also be used as a timed output - max 4 min.)
Notes • The thrust capacitors are supplied in the operators packages
Model
Part Number
455D Control board
790917
Manual available visit www.faac.co.uk