455D

TECHNICAL SPECIFICATIONS

Power supply voltage

230 Vac (+6% - 10%) - 50 Hz

Absorbed power Motor max. load

10 W

800 W 500 mA

Accessories max. load Electric lock max. load

15VA

Operating ambient temperature

-20 °C to +55 °C

Protection fuses

2

Open/Open free leaf/Stop (closed)/Opening safety devices/Closing safety devices/power supply & earth / opening and closing limit switches

Terminal board inputs

Flashing lamp/motors/24Vdc power supply accessories/24 Vdc Indicator light/fail safe/ 12 Vac electric lock power supply

Terminal board outputs

Rapid connector Status signalling

Decoding cards/RP card receivers

via display

455 D board can control one or two operators

FUNCTIONS (PROGRAMMING BY DISPLAY AND PUSH-BUTTONS) Basic programming Function logics

Semi-automatic / Automatic / Safety / “stepped” semi-automatic / “stepped”automatic / “stepped” safety / Semi-automatic B / “Dead man” C

Open and closing time

Programmable (0 to 120 s) Programmable (0 to 4 min.) Programmable (0 to 4 min.)

Pause time

Closing leaf delay

Thrust power

Adjustable on 50 levels for each motor

Simple (work time self-learning of both leaves simultaneously) Complete (work time “manual” learning of each leaf with possibility to activate timed travel limit “decelerations”)

Work times learning (0 to 120 s)

Deceleration

timed / with limit switch / with gatecoder

Advanced programming Maximum torque at initial thrust

Selectable (useful for heavy-weight leaves)

Final stroke on closing

Selectable (makes the locking of the electric lock easier) Selectable (makes the release of the electric lock easier)

Reversing stroke

Pre-flashing

5 s (selectable)

Opening leaf delay

2 s (can be disabled)

Closing photocell logic Fail safe (photocell test) Electric lock on second leaf

Reverses on release/reverses immediately

Selectable Selectable

Cycle count

Selectable (updating of a “count-down”- max. setting 99.000 thousand cycles)

Selectable (when the number of cycles set by program is “reached”, the system activates a preflashing of 8 s before every opening movement)

Service request

Indicator light/timed output

Selectable (the indicator light output can also be used as a timed output - max 4 min.)

Notes • The thrust capacitors are supplied in the operators packages

Model

Part Number

455D Control board

790917

Manual available visit www.faac.co.uk