Product catalogue

E145S

This control board has been designed to control both swing-leaf and sliding-leaf gates for vehicle and pedestrian access control. • The E145S comes with safezone technology - obstacle detection and reversal on contact. (when the optional encoder is used). • Greentech are solutions which save up to 90% of power compared to traditional systems ( thanks to the innovative power supply switching systems. • The board is able to automatically adapt to different input voltages (from 90V~ to 260V~), maintaining a constant output voltage to accessories. • Added connectivity - the new board supports BUS 2EASY and can be programmed from using a smart device with Simply Connect or from USB key pre-programmed in Easyboard • Backward compatible - can be fitted to existing installations • Can automatically find the deceleration and stop points during setup when using the safecoder with physical stops. • In event of power failure the optional absolute encoder keeps the leaf position memorised • It has embedded radio decoding in order to support only orginal FAAC transmitters (upto 1600 radio codes can be stored). It also has a 5 pin connector for plugging existing radio controls. • Built in timer (programmed via Simply Connect or from USB Key pre-programmed in Easyboard) • Traditional and Bus photocell inputs. • Event log (via Simply Connect) • 2 inputs for 8.2 kohm safety edges direct on the board with no need for a separate controller. 2 programming levels are available from the board (BASIC and ADVANCED), using buttons and LCD display, 3rd level with Simply Connect of from USB Key pre-programmed in Easyboard.This board also allows you the option to program using a smart device with Simply Connect of from USB key pre-programmed in Easyboard. With the Easyboard programming software you can choose whether to follow the wizard guided installation or customise your system in all its parts.

Energy Savings

Hypothesis: Residential Energy Price = 0.17£/KWh*

Manual available visit www.faac.co.uk

E145

Standby saving W Saved/hour KWh saved/day

11.4 0.27

TOT KW/h saved/year TOT Kg CO2 avoided/year

100

53

Money saved a year

£17.00

* Italian average price and CO2 factor

TECHNICAL SPECIFICATIONS

Mains primary power supply Power absorbed from mains

With power supply switching from 90V~ to 260V~; 50/60Hz

stand by =4W

sleep <2W*

MAX~ 400W

MAX load for motors

800W

Accessories power supply

24V

+24V MAX 500 mA

BUS-2EASY MAX 500mA

MAX accessories current

LOCK (FAAC) 12V~/24V

LOCK (not FAAC) 24V 500mA (3A peak)

Operating ambient temperature Power supply safety fuses

from -20 o C to +55 o C

F1=F10AH250V

Work time

self learned through SETUP- (max 4 min and 10 sec)

Pause time

Programmable (from 0 to 9 min and 50 sec)

Motor Power

Programmble on 50 levels

Connector inputs

Decoder/minidec/RP, X-com, XF433/868 Module, USB-A, USB-B

Terminal board inputs

Mains power supply from 90 to 260V~ inputs from IN1 to IN5, limit switch, BUS-2EASY Flashing lamp, Motors, Electric lock (LOCK1 and LOCK2), OUT1 and OUT2 (programmble), Acces sories power supply

Terminal board outputs

* Function that can be enabled from a PC/MAC * Function that can be enabled from a PC/MAC

Model E145S

Part Number

790076

118

Made with FlippingBook - Online Brochure Maker