Product catalogue
E145S
This control board has been designed to control both swing-leaf and sliding-leaf gates for vehicle and pedestrian access control. • The E145S comes with safezone technology - obstacle detection and reversal on contact. (when the optional encoder is used). • Greentech are solutions which save up to 90% of power compared to traditional systems ( thanks to the innovative power supply switching systems. • The board is able to automatically adapt to different input voltages (from 90V~ to 260V~), maintaining a constant output voltage to accessories. • Added connectivity - the new board supports BUS 2EASY and can be programmed from using a smart device with Simply Connect or from USB key pre-programmed in Easyboard • Backward compatible - can be fitted to existing installations • Can automatically find the deceleration and stop points during setup when using the safecoder with physical stops. • In event of power failure the optional absolute encoder keeps the leaf position memorised • It has embedded radio decoding in order to support only orginal FAAC transmitters (upto 1600 radio codes can be stored). It also has a 5 pin connector for plugging existing radio controls. • Built in timer (programmed via Simply Connect or from USB Key pre-programmed in Easyboard) • Traditional and Bus photocell inputs. • Event log (via Simply Connect) • 2 inputs for 8.2 kohm safety edges direct on the board with no need for a separate controller. 2 programming levels are available from the board (BASIC and ADVANCED), using buttons and LCD display, 3rd level with Simply Connect of from USB Key pre-programmed in Easyboard.This board also allows you the option to program using a smart device with Simply Connect of from USB key pre-programmed in Easyboard. With the Easyboard programming software you can choose whether to follow the wizard guided installation or customise your system in all its parts.
Energy Savings
Hypothesis: Residential Energy Price = 0.17£/KWh*
Manual available visit www.faac.co.uk
E145
Standby saving W Saved/hour KWh saved/day
11.4 0.27
TOT KW/h saved/year TOT Kg CO2 avoided/year
100
53
Money saved a year
£17.00
* Italian average price and CO2 factor
TECHNICAL SPECIFICATIONS
Mains primary power supply Power absorbed from mains
With power supply switching from 90V~ to 260V~; 50/60Hz
stand by =4W
sleep <2W*
MAX~ 400W
MAX load for motors
800W
Accessories power supply
24V
+24V MAX 500 mA
BUS-2EASY MAX 500mA
MAX accessories current
LOCK (FAAC) 12V~/24V
LOCK (not FAAC) 24V 500mA (3A peak)
Operating ambient temperature Power supply safety fuses
from -20 o C to +55 o C
F1=F10AH250V
Work time
self learned through SETUP- (max 4 min and 10 sec)
Pause time
Programmable (from 0 to 9 min and 50 sec)
Motor Power
Programmble on 50 levels
Connector inputs
Decoder/minidec/RP, X-com, XF433/868 Module, USB-A, USB-B
Terminal board inputs
Mains power supply from 90 to 260V~ inputs from IN1 to IN5, limit switch, BUS-2EASY Flashing lamp, Motors, Electric lock (LOCK1 and LOCK2), OUT1 and OUT2 (programmble), Acces sories power supply
Terminal board outputs
* Function that can be enabled from a PC/MAC * Function that can be enabled from a PC/MAC
Model E145S
Part Number
790076
118