Product catalogue

740D

Electronic Control Units and Accessories

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS

Power supply voltage

230 Vac (+6% -10%) 50 (60) Hz

Absorbed power Motor max. load

10 W

1000 W

Accessories max. load

0,5 A

Operating ambient temperature

-20 °C to +55 °C

Protection fuses

2

Automatic/”Stepped” automatic/Semi-automatic/Safety/Semi-automatic B/ “Dead man” C/ Stepped” semi-automatic /Mixed logic B+C

Function logics

Work time Pause time Thrust power

Programmable (0 to 4 min.) Programmable (0 to 4 min.) Adjustable on 50 levels

Terminal board inputs

Open/Partial Open/Opening safety device/ Closing safety device/Stop/Edge/Power supply & earth

Connector inputs

Opening and closing limit switches/ Encoder (optional)

Terminal board outputs

Flashing lamp Motor 24 Vdc Accessories power supply 24 Vdc Indicator light /timed output Failsafe

Rapid connector

5-pin fitting for Minidec cards, Decoder or RP receivers 3 keys (+, -, F) and display, “basic“ and “advanced“ mode Function logics - Pause time - Thrust force - Gate direction

Programming

“Basic” mode programmable functions

Torque at initial thrust - Brake - Failsafe – Pre-flashing – Indicator light/Timed output – Logic for safety devices at opening and closing - Encoder for anti-crushing electronic safety device, deceleration control and partial opening - Decelerations - Partial opening time – Work time - Service request – Cycle counter

“Advanced” mode programmable functions

Model

Part Number

740D control board

202269

Manual available visit www.faac.co.uk

E721 TECHNICAL SPECIFICATIONS

Power supply voltage

230 Vac (+6% -10%) 50 Hz

Absorbed power Max. motor load

10 W 10 A

Accessory power supply Accessory max. current

24 Vdc 500 mA

Operating ambient temperature

-20°C to +55°C F1= TIA-250V~

Protection fuses

Automatic (A)/Automatic (A1)/Semi-automitic (E)/Automatic Timer (At)/Automatic with reverse Pause(SA)/ Parking automatic (AP)/Dead man (C)/Automatic safety (S)/”Stepped” safety (SP)/”Stepped” semi-auto matic (EP)/Semi-automatic (B)/Mixed logic (BC)

Function logics

Work time Pause time Motor power

Programmable (from 0 to 9 min and 50 sec) Programmable (from 0 to 9 min and 50 sec)

Programmable over 50 levels

BUS 2 Easy 5 inputs (open A, open B/close, stop, safety device at opening, safety device at closure) Stop or Open B/Close can be programmed as safety edge inputs. 1 programmable output 24V, 100mA (fail-safe, alarm, indicator light, courtesy light, activated with 2-channel radio), flashing lamp

Inputs

Outputs

Rapid connectors

OMNIDEC (XF 433 or XF 868) 3 keys (+, -, F) and LCD display

Programming

Logic, Pause time A, Pause time B, Thrust, Opening speed, Closing speed, Deceleration spaces, Pre-flashing, Opening safety devices logic, Closing safety devices logic, Obstacle sensitivity, Partial opening, cycle counter, master & slave function

Programmable functions

Speed

Programmable over 10 levels

Model

Part Number

E721

63002485

Manual available visit www.faac.co.uk

Made with FlippingBook - Online Brochure Maker