Product catalogue
624 BLD
Electronic Control Units and Accessories
TECHNICAL SPECIFICATIONS
Power supply voltage
230 Vac (+6%-10%) 50 (60) Hz
Absorbed power Motor max. load
7 W
300 W 24 Vdc 500 mA
Accessories power supply Accessories max. current Operating ambient temperature TECHNICAL SPECIFICATIONS
-20 °C to +55 °C
Protection fuses
F1=F 5A-250 V F2=T 0,8A-250V
Automatic, Automatic 1, Semi-automatic, Parking, Parking-Automatic, Condominium, Condominium-Automatic, FAAC bollard, Dead man, Remote, Custom
Function logics
Work time Pause time Motor thrust
Programmable (0 to 4 min) Programmable (0 to 4 min) Programmable on 50 levels
Terminal board inputs
Loop 1, Loop 2, Open, Close, Closing safety devices, Stop, Emergency, 230 Vac power supply & Earth
Connector inputs
Opening and closing limit switches, motor capacitor, beam release sensor
Terminal board outputs
Flashing light, fan, motor, 24 Vdc power supply, fail-safe, status output, 24 Vdc indicator light, BUS
Rapid connector
5-pin fitting for Minidec card, decoder or RP/RP2 receiver
Programming
3 keys /+, -, F) and display
Logic, Pause time, Thrust, Loop l and 2, Torque at initial thrust, Pre-flashing, Slow closing, Deceleration time, Work time, Indicator light output, Fail-safe output, Status output, BUS output, Service Request (cycle counter)
Programmable functions
Programmable outputs
4 programmable outputs in 18 different functions
Real time auto-calibration, sensitivity independent from loop geometry, loop operating frequency adjustment, message of “busy loop” with LED display, loop status addressable to programmable outputs, adjustment time over 2 levels.
Buit-in detector, 2 independent channels
Model
Part Number
624 BLD
2022715
Manual available visit www.faac.co.uk
E614
TECHNICAL SPECIFICATIONS
Power supply voltage
230 V ~ 50(60) Hz
Motor max power
150 W 500 mA
Max accessories load
Accessories power supply
24V
Programming Operating logic
LED display and buttons
EP-A-AP-B-BC-C-P
Logic, Pause time, Opening/Closing power, Opening/Closing speed, Work time, Cycle counter for service, service request, warning light output, Failsafe output, Status output, Beam LED lighting output, traffic light head output, battery operation, pre-flashing time, Stop, exits delay, Master-Slave
Programmable functions
Work time Pause time Thrust power
Programmable (0 to 9.5 min) Programmable (0 to 9.5min) Programmable on 50 levels Programmable on 10 levels
Speed adjustment Terminal board inputs Terminal board outputs
Loop1, Loop2, Open, Close, Stop, Emergency, Battery, BUS 2easy, Power supply 24V flashing lamp, Motor, Accessories supply 24V, 4 programmable outputs XF433/868 Module for OmniDEC decoding, USB, Traffic light indicator head, Beam LED lighting
Rapid connector Protection fuses
1 (2.5A) + self-resetting fuses
Operating ambient temperature
-20°C to +55°C
Model
Part Number
Manual available visit www.faac.co.uk
E614
63001034
Made with FlippingBook - Online Brochure Maker