Product catalogue
413
230V
Use
Use
Model
Model
Control unit
Part Number
Part Number
Single-leaf max. length (m)
Single-leaf max. length (m)
Use frequency (cycles/day)
Use frequency (cycles/day)
413
1.80 (2.5 with electric lock)
30
104413
413 LS
1.80 (2.5 with electric lock)
30
104414
The package contains: an electro-mechanical operator, installation accessories, a release key, a thrust capacitor 6.3 µF 400 V.
COMPONENTS AND SPECIFIC ACCESSORIES
Manual release key 7131005
Manual release keyring UK-Keyring
455D Control board 790917
E145S control board 790076
End User handover booklet N-DOC1
Safecoder 404040 *requires E145S
Plug in receiver/decoder 787854
Pair of photocells (XP20D) 785102
Two channel transmitter 787009
TECHNICAL SPECIFICATIONS OF 413 230V
413
413 LS
413
413 LS
Power supply
230 V ac
Leaf max. length (*)
2.5m
Power Current
250 W
Type and frequency of use at 20 °C Indicativemaximum hourly cycles at 20 °C
S3 - 30%
S3 - 35%
1.1 A
~30
Thermal protection
140 °C 6.3 µf
Operating ambient temperature
-20 °C to +55 °C
Capacitor
Weight of operator
6.5 kg
Thrust
200 daN
Dimensions (L x D x H) in mm
785 x 105 x 148
Rod stroke
300mm(350mmwithoutmechanicalstops)
Protection class
IP 54
Rod extension speed
1.6 cm/sec
Travel limit microswitches
NO
YES
Opening and closing mechanical stops
YES
(*) Use of the electric lock is recommended over 1.80 m
Notes • For obstacle detection with E145 board use safety edges and/or safecoder. For obstacle detection with 455D use safety edges. • Control board 455D or E145 must be used to control operators with travel limit device/s (Mod. LS).
Useful Accessories
Keypads
Safety Edges
Photocells
Prox readers
Made with FlippingBook - Online Brochure Maker