E124

Electronic Control Units and Accessories

TECHNICAL SPECIFICATIONS

Power supply voltage Absorbed power Motor max. current Accessory power supply Accessory max. current

230 Vac (+6%-10%) 50 (60) Hz 4 W Stand-by approx 400 W max.

7 A

24 Vdc

500 mA 24 Vdc - 500 mA BUS - 2 Easy

Operating ambient temperature

-20°C to +55°C

Protection fuses

power card 2.5A control board self resetting

Automatic (A), Semi-automatic (E), Automatic 1 (A1). "Stepped" automatic (AP), Dead man (C), Automatic safety (S), Stepped safety (SP), “Stepped” semi-automatic (EP) Semi-automatic B (B), Mixed logic (BC), Custom (customisable, programmable by the installer via PC)

Function logics

Work time Pause time Motor power

Programmable (from 0 to 10 min.) Programmable (from 0 to 10 min.)

Adjustable over 50 levels

BUS 2 Easy, inputs completely programmable via PC (open A, open B, close, priority open, priority close, emergency close, emergency open, stop, safety device at opening, safety device at closure) Inputs for 4 limits switches (open, close, motor 1/motor 2), connection inputs for 2 motors, encoders

Inputs

Outputs

2 programmable multifunction outputs

Rapid connectors

OMNIDEC (XF868), 5 pin board connection for Minidec, decoder, RP/RP2 receiver

Programming

3 keys (+, -, F) and LCD display, via PC with USB cable, via PC

Logic, pause time a, pause time b, thrust, speed, deceleration spaces, leaf delay, reverse-stroke, soft-touch, stroke at opening and closing, initial thrust, deceleration speed, indicator

Programmable functions

lamp, fail-safe, programming of 2 Easy devices, service request, power-safe, battery charger timer function, battery operation, clock, time-out, pre-flashing time, motor type, encoder sensitivity

Speed

Adjustable over 10 levels

Model

Part Number

E124

790284

Manual available visit www.faac.co.uk

E 024 S

TECHNICAL SPECIFICATIONS

Power supply voltage

230 Vac (+6%-10%) 50 Hz

Absorbed power Motor max. load

4 W

150 W x 2

Accessories max. current (+24V) BUS accessories max. current Operating ambient temperature

250 mA 400 mA

-20 °C to +55 °C

Protection fuses Function logics

F1 = self-resetting; - F2 = T2A-250V

EP, A, E, AP, A1, B, C

Work time (time-out)

5 minute (fixed)

Pause time

Varies according to learning (0 to 10 min) Open A, Open B, Stop, BUS 2 Easy Power supply battery - module XF 868

Terminal board inputs

Connector inputs

Terminal board outputs Programmable functions

Motors, flashing lamp, power supply to accessories, electric lock, service light contact (90 sec fixed)

Logic (A, E, AP, EP, A, B, C), Speed (high/low), Force ( 4 levels)

Learning functions

Pause time, leaf 2 delay at closing

Integrated radio channels type

DS, SLH (max 250 channels)

Manual available visit www.faac.co.uk

Model

Part Number

E024 S

790286

117

Made with FlippingBook - Online Brochure Maker